VCFRONT_a151 — Pump Pt Low RPMC Bang
Full alert identifier: VCFRONT_a151_pumpPtLowRPMCBang
Alert description
The motor has a circuit warning. Powertrain performance may be limited.
Potential impact
The powertrain pump will not run. Powertrain performance may be limited. A reset will occur to attempt to clear the fault.
Set condition
A non-zero brushless motor RPM below the RPM target is not increasing for some time.
Clear condition
Pump resumes running normally at RPM target.
Signals to check
These diagnostic fields are associated with VCFRONT_a151. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
RPM Actual
VCFRONT_
|
RPM |
RPM Target
VCFRONT_
|
RPM |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a151.