Skip to content

VCFRONT_a152 — Thml Fan Low RPMC Bang

Full alert identifier: VCFRONT_a152_thmlFanLowRPMCBang

Alert description

The motor has a circuit warning. HVAC cabin cooling (air conditioning) and powertrain performance may be limited.

Potential impact

The thermal fan will not run. HVAC cabin cooling (air conditioning) and powertrain performance may be limited. A reset will occur to attempt to clear the fault.

Set condition

A non-zero brushless motor RPM below the RPM target is not increasing for some time.

Clear condition

Pump resumes running normally at RPM target.

Signals to check

These diagnostic fields are associated with VCFRONT_a152. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
RPM Actual VCFRONT_a152_RPMActual RPM
RPM Target VCFRONT_a152_RPMTarget RPM

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a152.

Browse all VCFRONT alert codes