Skip to content

VCFRONT_a150 — Pump Chiller Low RPMC Bang

Full alert identifier: VCFRONT_a150_pumpChillerLowRPMCBang

Alert description

The motor has a circuit warning. Powertrain performance may be limited.

Potential impact

The chiller pump will not run. Powertrain performance may be limited. A reset will occur to attempt to clear the fault.

Set condition

A non-zero brushless motor RPM below the RPM target is not increasing for some time.

Clear condition

Pump resumes running normally at RPM target.

Signals to check

These diagnostic fields are associated with VCFRONT_a150. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
RPM Actual VCFRONT_a150_RPMActual RPM
RPM Target VCFRONT_a150_RPMTarget RPM

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a150.

Browse all VCFRONT alert codes