VCFRONT_a134 — Fused High eFuse Trip

Full alert identifier: VCFRONT_a134_fusedHighEFuseTrip

Alert description

The front vehicle controller (VCFRONT) fused high current eFuse circuit is open (tripped), interrupting low voltage (LV) power feed to the coolant pumps and condenser fan. HVAC cabin cooling (air conditioning) and powertrain performance may be limited.

Potential impact

The coolant pumps and condenser fan will be unavailable. As a result, the power conversion system (PCS) temperature may exceed normal operational range. HVAC cabin cooling (air conditioning) and powertrain performance may be limited.

Set condition

VCFRONT detects the fused high current eFuse circuit is open (tripped).

Clear condition

VCFRONT no longer detects the fused high current eFuse circuit as open (tripped), or the vehicle enters a state where the eFuse is expected to be open (off).

Signals to check

These diagnostic fields are associated with VCFRONT_a134. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Fused High Current VCFRONT_a134_fusedHighCurrent A
Fused High Temp VCFRONT_a134_fusedHighTemp degC
Fused High Voltage VCFRONT_a134_fusedHighVoltage V
Vbat Fused E Fuse Remaining Retries VCFRONT_a134_vbatFusedEFuseRemainingRetries —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a134.

Browse all VCFRONT alert codes