VCFRONT_a134 — Fused High eFuse Trip
Full alert identifier: VCFRONT_a134_fusedHighEFuseTrip
Alert description
The front vehicle controller (VCFRONT) fused high current eFuse circuit is open (tripped), interrupting low voltage (LV) power feed to the coolant pumps and condenser fan. HVAC cabin cooling (air conditioning) and powertrain performance may be limited.
Potential impact
The coolant pumps and condenser fan will be unavailable. As a result, the power conversion system (PCS) temperature may exceed normal operational range. HVAC cabin cooling (air conditioning) and powertrain performance may be limited.
Set condition
VCFRONT detects the fused high current eFuse circuit is open (tripped).
Clear condition
VCFRONT no longer detects the fused high current eFuse circuit as open (tripped), or the vehicle enters a state where the eFuse is expected to be open (off).
Signals to check
These diagnostic fields are associated with VCFRONT_a134. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Fused High Current
VCFRONT_
|
A |
Fused High Temp
VCFRONT_
|
degC |
Fused High Voltage
VCFRONT_
|
V |
Vbat Fused E Fuse Remaining Retries
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a134.