VCFRONT_a127 — Vcleft eFuse Trip
Full alert identifier: VCFRONT_a127_vcleftEFuseTrip
Alert description
The front vehicle controller (VCFRONT) has opened the low voltage (LV) power feed circuit (eFuse) to the left vehicle controller (VCLEFT), interrupting power supply to VCLEFT.
Potential impact
Functions on the left side of the vehicle may be limited or unavailable.
Set condition
VCFRONT detects the eFuse circuit gating low voltage (LV) power feed to VCLEFT as open (tripped).
Clear condition
VCFRONT no longer detects the eFuse circuit gating low voltage (LV) power feed to VCLEFT as open (tripped) after a retry or sleep cycle, or the vehicle enters a state where the eFuse is expected to be open (off).
Signals to check
These diagnostic fields are associated with VCFRONT_a127. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Vcleft E Fuse Current
VCFRONT_
|
A |
Vcleft E Fuse Remaining Retries
VCFRONT_
|
— |
Vcleft E Fuse Temp
VCFRONT_
|
degC |
Vcleft E Fuse Voltage
VCFRONT_
|
V |