Skip to content

VCFRONT_a130 — Epas3p eFuse Trip

Full alert identifier: VCFRONT_a130_epas3pEFuseTrip

Alert description

The front vehicle controller (VCFRONT) has opened the low voltage (LV) power feed circuit (eFuse) to the primary electronic power steering controller (EPAS3P), interrupting power supply to EPAS3P.

Potential impact

Power steering functionality may be limited or unavailable.

Set condition

VCFRONT detects the eFuse circuit gating low voltage (LV) power feed to EPAS3P as open (tripped).

Clear condition

VCFRONT no longer detects the eFuse circuit gating low voltage (LV) power feed to EPAS3P as open (tripped) after a retry or sleep cycle, or the vehicle enters a state where the eFuse is expected to be open (off).

Signals to check

These diagnostic fields are associated with VCFRONT_a130. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Epas 3 P E Fuse Current VCFRONT_a130_epas3pEFuseCurrent A
Epas 3 P E Fuse Temp VCFRONT_a130_epas3pEFuseTemp degC
Epas 3 P E Fuse Voltage VCFRONT_a130_epas3pEFuseVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a130.

Browse all VCFRONT alert codes