Skip to content

VCFRONT_a128 — Vcright eFuse Trip

Full alert identifier: VCFRONT_a128_vcrightEFuseTrip

Alert description

The front vehicle controller (VCFRONT) has opened the low voltage (LV) power feed circuit (eFuse) to the right vehicle controller (VCRIGHT), interrupting power supply to VCRIGHT.

Potential impact

Functions on the right side of the vehicle may be limited or unavailable.

Set condition

VCFRONT detects the eFuse circuit gating low voltage (LV) power feed to VCRIGHT as open (tripped).

Clear condition

VCFRONT no longer detects the eFuse circuit gating low voltage (LV) power feed to VCRIGHT as open (tripped) after a retry or sleep cycle, or the vehicle enters a state where the eFuse is expected to be open (off).

Signals to check

These diagnostic fields are associated with VCFRONT_a128. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Vcright E Fuse Current VCFRONT_a128_vcrightEFuseCurrent A
Vcright E Fuse Remaining Retries VCFRONT_a128_vcrightEFuseRemainingRetries —
Vcright E Fuse Temp VCFRONT_a128_vcrightEFuseTemp degC
Vcright E Fuse Voltage VCFRONT_a128_vcrightEFuseVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a128.

Browse all VCFRONT alert codes