PCS2REXA_a142 — Ac Line Gdps Uncalibrated
Full alert identifier: PCS2REXA_a142_AcLineGdpsUncalibrated
Alert description
The Power Conversion System (PCS) AC line Gate Drive Power Supply (GDPS) has not been correctly calibrated
Potential impact
The PCS will use inaccurate GDPS calibration data, which may stress the AC line MOSFETS.
Set condition
The AC line GDPS calibration data is not present in NVM (AcLineGdpsDataMissing=1), or is not validated (AcLineGdpsDataOutOfSpec=1), or is stale (AcLineGdpsDataStale=1)
Clear condition
The PCS AC line GDPS calibration data is correctly calibrated
Signals to check
These diagnostic fields are associated with PCS2REXA_a142. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ac Line Gdps Data Missing
PCS2REXA_
|
— |
Ac Line Gdps Data Out Of Spec
PCS2REXA_
|
— |
Ac Line Gdps Data Stale
PCS2REXA_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a142.