PCS2REXA_a145 — Dcdc Hvdc Gdps Uncalibrated

Full alert identifier: PCS2REXA_a145_DcdcHvdcGdpsUncalibrated

Alert description

The Power Conversion System (PCS) DCDC HVDC Gate Drive Power Supply (GDPS) has not been correctly calibrated

Potential impact

The PCS will use inaccurate GDPS calibration data, which may stress the DCDC HVDC MOSFETs.

Set condition

The DCDC HVDC GDPS calibration data is not present in NVM (DcdcHvdcGdpsDataMissing=1), or is not validated (DcdcHvdcGdpsDataOutOfSpec=1), or is stale (DcdcHvdcGdpsDataStale=1)

Clear condition

The PCS DCDC HVDC GDPS calibration data is correctly calibrated

Signals to check

These diagnostic fields are associated with PCS2REXA_a145. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dcdc Hvdc Gdps Data Missing PCS2REXA_a145_DcdcHvdcGdpsDataMissing —
Dcdc Hvdc Gdps Data Out Of Spec PCS2REXA_a145_DcdcHvdcGdpsDataOutOfSpec —
Dcdc Hvdc Gdps Data Stale PCS2REXA_a145_DcdcHvdcGdpsDataStale —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a145.