PCS2REXA_a146 — Ac Line Shared Current Connection Issue
Full alert identifier: PCS2REXA_a146_acLineSharedCurrentConnectionIssue
Alert description
The Power Conversion System (PCS2) detects that the DCAC converter's shared leg current is not shared evenly when the legs are shorted by either the AC harness or the AC relay.
Potential impact
The DCAC converters will have reduced power capabilities.
Set condition
The shared leg current difference exceeds the expected threshold.
Clear condition
The shared leg current is an even split of the total current.
Signals to check
These diagnostic fields are associated with PCS2REXA_a146. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ac Harness L 2 L 3 Shorted
PCS2REXA_
|
— |
Leg 1 Irms
PCS2REXA_
|
A |
Leg 2 Irms
PCS2REXA_
|
A |
Leg 3 Irms
PCS2REXA_
|
A |
Leg N Irms
PCS2REXA_
|
A |
Legs Paralleled By Relay
PCS2REXA_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a146.