Skip to content

PCS2REXA_a154 — Adc Reference Uncalibrated

Full alert identifier: PCS2REXA_a154_adcReferenceUncalibrated

Alert description

The Power Conversion System (PCS) ADC reference has not been correctly calibrated.

Potential impact

The PCS will use the default ADC reference of 1.0.

Set condition

The ADC reference data is not present in non-volatile memory (adcReferenceDataMissing=1) or is not validated (adcReferenceOutOfSpec=1).

Clear condition

The PCS ADC reference data is correctly calibrated.

Signals to check

These diagnostic fields are associated with PCS2REXA_a154. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Adc Reference Data Missing PCS2REXA_a154_adcReferenceDataMissing —
Adc Reference Out Of Spec PCS2REXA_a154_adcReferenceOutOfSpec —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a154.

Browse all PCS2REXA alert codes