PCS2REXA_a057 — Cyclo A Tank Uncalibrated

Full alert identifier: PCS2REXA_a057_cycloATankUncalibrated

Alert description

DCAC converter A (DCACA) resonant tank has not been fully calibrated

Potential impact

DCAC operation allowed with default resonant tank parameters at reduced surge current limit

Set condition

A tank capacitance or inductance measurement for DCACA is not recorded in Non-Volatile Memory (NVM)

Clear condition

DCACA resonant tank calibration data is within specification

Signals to check

These diagnostic fields are associated with PCS2REXA_a057. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Leakage Inductance Defined PCS2REXA_a057_leakageInductanceDefined —
Magnetizing Inductance Defined PCS2REXA_a057_magnetizingInductanceDefined —
Tank Capacitance Defined PCS2REXA_a057_tankCapacitanceDefined —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a057.