PCS2REXA_a012 — Cyclo A Tank Over Current
Full alert identifier: PCS2REXA_a012_cycloATankOverCurrent
Alert description
The DCAC converter A (DCACA) resonant tank current goes above the allowed current threshold
Potential impact
AC charging and AC outlet functionality may be limited or paused
Set condition
The pack side DCDC converter (DCACA) resonant tank current goes above the allowed current threshold
Clear condition
The DCAC system retries
Signals to check
These diagnostic fields are associated with PCS2REXA_a012. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Cyclo A Tank Over Current Trip
PCS2REXA_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a012.