Skip to content

PCS2REXA_a018 — Dcdc B Tank Over Current

Full alert identifier: PCS2REXA_a018_dcdcBTankOverCurrent

Alert description

The DC link side DCDC converter (DCDCB) resonant tank current goes above the allowed current threshold

Potential impact

DCDC functionality may be limited or paused

Set condition

The DC link side DCDC converter (DCDCB) resonant tank current goes above the allowed current threshold

Clear condition

The DCDC system retries

Signals to check

These diagnostic fields are associated with PCS2REXA_a018. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dcdc B Tank Over Current Trip PCS2REXA_a018_dcdcBTankOverCurrentTrip
0
COMPH TRIP
1
COMPL TRIP
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a018.

Browse all PCS2REXA alert codes