Skip to content

EGGRIGHT1_a254 — Seat Back HC Enc Stl Dbg

Full alert identifier: EGGRIGHT1_a254_seatBackHCEncStlDbg

Alert description

The backrest motor encoder has unexpectedly stalled

Potential impact

Encoder may increment incorrectly if obstruction encountered

Set condition

Current draw exceeds 70% of stall limit and encoder not moving for 100ms

Clear condition

The motor is not in a movement state or it is but has not detected high current motor stall

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a254. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Current EGGRIGHT1_a254_seatMotorCurrent A
Seat Motor D Current EGGRIGHT1_a254_seatMotorDCurrent A
Seat Motor Pos Real EGGRIGHT1_a254_seatMotorPosReal mm
Seat Motor State EGGRIGHT1_a254_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a254.

Browse all EGGRIGHT1 alert codes