Skip to content

EGGRIGHT1_a234 — Seat Enc Stall Back

Full alert identifier: EGGRIGHT1_a234_seatEncStallBack

Alert description

The motor isn't providing encoder feedback

Potential impact

Memory recall will be unavailable

Set condition

Current draw is nonzero and not stalling but encoder values don't increase

Clear condition

The motor exits the motor stopped state

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a234. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Calibrated EGGRIGHT1_a234_seatMotorCalibrated —
Seat Motor Current EGGRIGHT1_a234_seatMotorCurrent A
Seat Motor State EGGRIGHT1_a234_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back EGGRIGHT1_a234_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward EGGRIGHT1_a234_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a234.