EGGRIGHT1_a235 — Seat Enc Stall Lift
Full alert identifier: EGGRIGHT1_a235_seatEncStallLift
Alert description
The motor isn't providing encoder feedback
Potential impact
Memory recall will be unavailable
Set condition
Current draw is nonzero and not stalling but encoder values don't increase
Clear condition
The motor exits the motor stopped state
Signals to check
These diagnostic fields are associated with EGGRIGHT1_a235. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Seat Motor Calibrated
EGGRIGHT1_
|
— |
Seat Motor Current
EGGRIGHT1_
|
A |
Seat Motor State
EGGRIGHT1_
|
— |
Seat Switch Back
EGGRIGHT1_
|
— |
Seat Switch Forward
EGGRIGHT1_
|
— |
Check other alerts