EGGRIGHT1_a251 — Seat Lift Stall Debug

Full alert identifier: EGGRIGHT1_a251_seatLiftStallDebug

Alert description

The seat lift motor has unexpectedly stalled.

Potential impact

Motor will recalibrate if the stall is in an expected region, do nothing otherwise.

Set condition

Current draw exceeds stall limit.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a stall.

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a251. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Current EGGRIGHT1_a251_seatMotorCurrent A
Seat Motor D Current EGGRIGHT1_a251_seatMotorDCurrent A
Seat Motor Pos Real EGGRIGHT1_a251_seatMotorPosReal mm
Seat Motor State EGGRIGHT1_a251_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a251.