EGGRIGHT1_a252 — Seat Track HC Enc Stl Dbg
Full alert identifier: EGGRIGHT1_a252_seatTrackHCEncStlDbg
Alert description
The seat track motor encoder has unexpectedly stalled.
Potential impact
The seat track motor encoder may increment incorrectly if an obstruction is encountered.
Set condition
Current draw exceeded 70% of the stall limit, and the encoder did not move for 100ms.
Clear condition
The motor is not in a movement state. It may also be in a movement state, but has not detected a high current motor stall.
Signals to check
These diagnostic fields are associated with EGGRIGHT1_a252. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Seat Motor Current
EGGRIGHT1_
|
A |
Seat Motor D Current
EGGRIGHT1_
|
A |
Seat Motor Pos Real
EGGRIGHT1_
|
mm |
Seat Motor State
EGGRIGHT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a252.