EGGRIGHT1_a252 — Seat Track HC Enc Stl Dbg

Full alert identifier: EGGRIGHT1_a252_seatTrackHCEncStlDbg

Alert description

The seat track motor encoder has unexpectedly stalled.

Potential impact

The seat track motor encoder may increment incorrectly if an obstruction is encountered.

Set condition

Current draw exceeded 70% of the stall limit, and the encoder did not move for 100ms.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a high current motor stall.

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a252. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Current EGGRIGHT1_a252_seatMotorCurrent A
Seat Motor D Current EGGRIGHT1_a252_seatMotorDCurrent A
Seat Motor Pos Real EGGRIGHT1_a252_seatMotorPosReal mm
Seat Motor State EGGRIGHT1_a252_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—