EGGRIGHT1_a253 — Seat Tilt HC Enc Stl Dbg
Full alert identifier: EGGRIGHT1_a253_seatTiltHCEncStlDbg
Alert description
The seat tilt motor encoder has unexpectedly stalled.
Potential impact
The seat tilt motor encoder may increment incorrectly if an obstruction is encountered.
Set condition
Current draw exceeds 70% of the stall limit, and the encoder does not move for 100ms.
Clear condition
The motor is not in a movement state. It may also be in a movement state, but has not detected a high current motor stall.
Signals to check
These diagnostic fields are associated with EGGRIGHT1_a253. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Seat Motor Current
EGGRIGHT1_
|
A |
Seat Motor D Current
EGGRIGHT1_
|
A |
Seat Motor Pos Real
EGGRIGHT1_
|
mm |
Seat Motor State
EGGRIGHT1_
|
— |
Check other alerts