Skip to content

EGGRIGHT1_a253 — Seat Tilt HC Enc Stl Dbg

Full alert identifier: EGGRIGHT1_a253_seatTiltHCEncStlDbg

Alert description

The seat tilt motor encoder has unexpectedly stalled.

Potential impact

The seat tilt motor encoder may increment incorrectly if an obstruction is encountered.

Set condition

Current draw exceeds 70% of the stall limit, and the encoder does not move for 100ms.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a high current motor stall.

Signals to check

These diagnostic fields are associated with EGGRIGHT1_a253. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Current EGGRIGHT1_a253_seatMotorCurrent A
Seat Motor D Current EGGRIGHT1_a253_seatMotorDCurrent A
Seat Motor Pos Real EGGRIGHT1_a253_seatMotorPosReal mm
Seat Motor State EGGRIGHT1_a253_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT1_a253.

Browse all EGGRIGHT1 alert codes