Skip to content

EGGLEFTVC_a259 — Seat Abuse Buffer Full

Full alert identifier: EGGLEFTVC_a259_seatAbuseBufferFull

Alert description

The seat track abuse has been detected, maximum number of events per time exceeded

Potential impact

The seat track motor will be disabled

Set condition

The maximum number of operating events per time has been exceeded

Clear condition

Enough time has elapsed to allow normal motor operation

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a259. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cabin Tmp EGGLEFTVC_a259_cabinTmp degC
Seat Motor Calibrated EGGLEFTVC_a259_seatMotorCalibrated —
Seat Motor Current EGGLEFTVC_a259_seatMotorCurrent A
Seat Motor Pos Real EGGLEFTVC_a259_seatMotorPosReal mm
Seat Motor State EGGLEFTVC_a259_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back EGGLEFTVC_a259_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward EGGLEFTVC_a259_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a259.

Browse all EGGLEFTVC alert codes