EGGLEFTVC_a258 — Seat Abuse Buffer Warn

Full alert identifier: EGGLEFTVC_a258_seatAbuseBufferWarn

Alert description

Seat track motor abuse has been detected, with number of events within 5 minutes required to generate a warning exceeded

Potential impact

The seat track motor will be disabled if operation continues and maximum number of events within 5 minutes is exceeded

Set condition

The number of operating events per time period required to generate a warning for seat track motor abuse has been exceeded

Clear condition

Elapsed time greater than 5 minutes since last operation

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a258. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cabin Tmp EGGLEFTVC_a258_cabinTmp degC
Seat Motor Calibrated EGGLEFTVC_a258_seatMotorCalibrated —
Seat Motor Current EGGLEFTVC_a258_seatMotorCurrent A
Seat Motor Pos Real EGGLEFTVC_a258_seatMotorPosReal mm
Seat Motor State EGGLEFTVC_a258_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back EGGLEFTVC_a258_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward EGGLEFTVC_a258_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—