Skip to content

EGGLEFTVC_a257 — Seat Abuse Motor Stop

Full alert identifier: EGGLEFTVC_a257_seatAbuseMotorStop

Alert description

The seat has detected that the track motor has exceeded normal operating times

Potential impact

The seat track motor will be disabled

Set condition

The operating time has exceeded 120 seconds within 5 minutes

Clear condition

Elapsed time greater than 5 minutes since last operation

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a257. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cabin Tmp EGGLEFTVC_a257_cabinTmp degC
Seat Motor Calibrated EGGLEFTVC_a257_seatMotorCalibrated —
Seat Motor Current EGGLEFTVC_a257_seatMotorCurrent A
Seat Motor Pos Real EGGLEFTVC_a257_seatMotorPosReal mm
Seat Motor State EGGLEFTVC_a257_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back EGGLEFTVC_a257_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward EGGLEFTVC_a257_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a257.

Browse all EGGLEFTVC alert codes