Skip to content

EGGLEFTVC_a256 — Seat Abuse Motor Warn

Full alert identifier: EGGLEFTVC_a256_seatAbuseMotorWarn

Alert description

The seat has detected that the track motor is close to exceeding normal operating times

Potential impact

The seat track motor will be disabled if operation is continued and exceeds 120 seconds within 5 minutes

Set condition

The operating time has exceeded 90 seconds within 5 minutes

Clear condition

Elapsed time greater than 5 minutes since last operation

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a256. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cabin Tmp EGGLEFTVC_a256_cabinTmp degC
Seat Motor Calibrated EGGLEFTVC_a256_seatMotorCalibrated —
Seat Motor Current EGGLEFTVC_a256_seatMotorCurrent A
Seat Motor Pos Real EGGLEFTVC_a256_seatMotorPosReal mm
Seat Motor State EGGLEFTVC_a256_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back EGGLEFTVC_a256_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward EGGLEFTVC_a256_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a256.