Skip to content

EGGLEFTVC_a233 — Seat Enc Stall Tilt

Full alert identifier: EGGLEFTVC_a233_seatEncStallTilt

Alert description

The motor isn't providing encoder feedback

Potential impact

Memory recall will be unavailable

Set condition

Current draw is nonzero and not stalling but encoder values don't increase

Clear condition

The motor exits the motor stopped state

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a233. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Calibrated EGGLEFTVC_a233_seatMotorCalibrated —
Seat Motor Current EGGLEFTVC_a233_seatMotorCurrent A
Seat Motor State EGGLEFTVC_a233_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back EGGLEFTVC_a233_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward EGGLEFTVC_a233_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a233.

Browse all EGGLEFTVC alert codes