EGGLEFTVC_a235 — Seat Enc Stall Lift

Full alert identifier: EGGLEFTVC_a235_seatEncStallLift

Alert description

The motor isn't providing encoder feedback

Potential impact

Memory recall will be unavailable

Set condition

Current draw is nonzero and not stalling but encoder values don't increase

Clear condition

The motor exits the motor stopped state

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a235. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Calibrated EGGLEFTVC_a235_seatMotorCalibrated —
Seat Motor Current EGGLEFTVC_a235_seatMotorCurrent A
Seat Motor State EGGLEFTVC_a235_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back EGGLEFTVC_a235_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward EGGLEFTVC_a235_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—