Skip to content

EGGLEFTVC_a232 — Seat Enc Stall Track

Full alert identifier: EGGLEFTVC_a232_seatEncStallTrack

Alert description

The motor isn't providing encoder feedback

Potential impact

Memory recall will be unavailable

Set condition

Current draw is nonzero and not stalling but encoder values don't increase

Clear condition

The motor exits the motor stopped state

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a232. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Calibrated EGGLEFTVC_a232_seatMotorCalibrated —
Seat Motor Current EGGLEFTVC_a232_seatMotorCurrent A
Seat Motor State EGGLEFTVC_a232_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—
Seat Switch Back EGGLEFTVC_a232_seatSwitchBack
0
SNA
1
OFF
2
ON
3
FAULT
—
Seat Switch Forward EGGLEFTVC_a232_seatSwitchForward
0
SNA
1
OFF
2
ON
3
FAULT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a232.

Browse all EGGLEFTVC alert codes