Skip to content

EGGLEFTVC_a248 — Seat Track Stall Debug

Full alert identifier: EGGLEFTVC_a248_seatTrackStallDebug

Alert description

The seat track motor has unexpectedly stalled.

Potential impact

Motor will recalibrate if the stall is in an expected region, do nothing otherwise.

Set condition

Current draw exceeds stall limit.

Clear condition

The motor is not in a movement state. It may also be in a movement state, but has not detected a stall.

Signals to check

These diagnostic fields are associated with EGGLEFTVC_a248. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Seat Motor Current EGGLEFTVC_a248_seatMotorCurrent A
Seat Motor D Current EGGLEFTVC_a248_seatMotorDCurrent A
Seat Motor Pos Real EGGLEFTVC_a248_seatMotorPosReal mm
Seat Motor State EGGLEFTVC_a248_seatMotorState
0
STOPPED
1
MOVING UP
2
MOVING DOWN
3
RECALLING
4
CALIBRATING
5
UNDEFINED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGLEFTVC_a248.

Browse all EGGLEFTVC alert codes