EGGLEFTVC_a249 — Seat Tilt Stall Debug
Full alert identifier: EGGLEFTVC_a249_seatTiltStallDebug
Alert description
The seat tilt motor has unexpectedly stalled.
Potential impact
Motor will recalibrate if the stall is in an expected region, do nothing otherwise.
Set condition
Current draw exceeds stall limit.
Clear condition
The seat tilt motor is not in a movement state. It may also be in a movement state, but has not detected a stall.
Signals to check
These diagnostic fields are associated with EGGLEFTVC_a249. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Seat Motor Current
EGGLEFTVC_
|
A |
Seat Motor D Current
EGGLEFTVC_
|
A |
Seat Motor Pos Real
EGGLEFTVC_
|
mm |
Seat Motor State
EGGLEFTVC_
|
— |