DIREL_a028 — Phase Arms
Full alert identifier: DIREL_a028_phaseArms
Alert description
The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected the current sensor Root Mean Squared (RMS) current has exceeded the expected RMS threshold on Phase A.
Potential impact
DIx may not function as expected, including vehicle power being limited.
Set condition
The DIx ECU has detected the current sensor RMS current has exceeded the expected RMS threshold on Phase A.
Clear condition
DIx ECU no longer detects the current sensor RMS current exceeding the expected RMS threshold on Phase A. Repower the circuit or complete a sleep cycle.
Signals to check
These diagnostic fields are associated with DIREL_a028. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
I Arms Speed
DIREL_
|
RPM |
I Arms Torque
DIREL_
|
Nm |
Phase Airms
DIREL_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a028.