Skip to content

DIREL_a025 — Phase Apeak

Full alert identifier: DIREL_a025_phaseApeak

Alert description

The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an overcurrent event (or peak) in Phase A.

Potential impact

DIx may be inoperable.

Set condition

The DIx ECU has detected a peak in Phase A.

Clear condition

DIx ECU no longer detects a peak in Phase A. Begin a new drive cycle.

Signals to check

These diagnostic fields are associated with DIREL_a025. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ia DIREL_a025_Ia A
Motor Speed DIREL_a025_motorSpeed RPM
Torque Motor DIREL_a025_torqueMotor Nm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a025.

Browse all DIREL alert codes