DIREL_a026 — Phase Bpeak

Full alert identifier: DIREL_a026_phaseBpeak

Alert description

The Drive Inverter (DIx) Electronic Control Unit (ECU) has detected an overcurrent event (or peak) in Phase B.

Potential impact

DIx may be inoperable.

Set condition

The DIx ECU has detected a peak in Phase B.

Clear condition

DIx ECU no longer detects a peak in Phase B. Begin a new drive cycle.

Signals to check

These diagnostic fields are associated with DIREL_a026. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ib DIREL_a026_Ib A
Motor Speed DIREL_a026_motorSpeed RPM
Torque Motor DIREL_a026_torqueMotor Nm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a026.