Skip to content

CP_a118 — Iec Combo Lock Up

Full alert identifier: CP_a118_iecComboLockUp

Alert description

Charge port detected a CCS lockup

Potential impact

This information is not available in the alert reference.

Set condition

This information is not available in the alert reference.

Clear condition

This information is not available in the alert reference.

Signals to check

These diagnostic fields are associated with CP_a118. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cable Connected CP_a118_cableConnected —
Ccs Manager State CP_a118_ccsManagerState
0
DISCONNECTED
1
CONNECTED
2
SETUP
3
CONTRACT AUTH
4
CHARGE PROCESS
5
SHUTDOWN
6
FAULTED
7
PAUSED
—
Evcc State CP_a118_evccState
0
INIT
1
WAIT FOR HANDSHAKE
2
COMMS ESTABLISHED
3
COMMS TIMEOUT
4
COMMS SHUTDOWN
5
COMMS PAUSED
6
COMMS FAULT
—
Evcc Task Mia Time CP_a118_evccTaskMiaTime ms
Sdp State CP_a118_sdpState
0
INIT
1
ACTIVE
2
SUCCESS
3
SIDE CHANNEL REQUESTS
4
SIDE CHANNEL REQUESTS DONE
5
FAULT
—
Sdp Task Mia Time CP_a118_sdpTaskMiaTime ms
Slac State CP_a118_slacState —
Tcp Ip Task Mia Time CP_a118_tcpIpTaskMiaTime ms
Show 3 more fields
Signal Unit
Tesla V 2 G State CP_a118_teslaV2gState
0
INIT
1
WAIT FOR COMMS
2
COMMS ESTABLISHED
3
COMMS SHUTDOWN
4
COMMS TIMEOUT
—
Tesla V 2 G Task Mia Time CP_a118_teslaV2gTaskMiaTime ms
V 2 G Task Mia Time CP_a118_v2gTaskMiaTime ms

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a118.

Browse all CP alert codes