CP_a120 — Combo Adapter Foldback
Full alert identifier: CP_a120_comboAdapterFoldback
Alert description
The charge port (CP) electronic control unit (ECU) detected that the Combined Charging System (CCS) Combo 1 Adapter temperature is higher than expected. The charging rate may be reduced.
Potential impact
The charging rate may be reduced or charging may be unexpectedly interrupted.
Set condition
The CP ECU detects that the CCS Combo 1 Adapter temperature is higher than acceptable operational range.
Clear condition
The charge cable is removed from the charge port.
Signals to check
These diagnostic fields are associated with CP_a120. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Charge Current
CP_
|
A |
Charge Voltage
CP_
|
V |
Dc Pin Temp
CP_
|
C |
New Proximty V
CP_
|
V |
Old Proximty V
CP_
|
V |
Check other alerts