Skip to content

CP_a163 — Cover Open Dc Chg Blocked

Full alert identifier: CP_a163_coverOpenDcChgBlocked

Alert description

DC charging is unavailable because the charge port (CP) electronic control unit (ECU) has detected that the high voltage (HV) back cover and/or CP AC charging connector are not present on the back of the CP inlet.

Potential impact

DC charging will be unavailable.

Set condition

The CP ECU detects the HV back cover and/or charge port AC charging connector are not present.

Clear condition

The CP ECU detects the HV back cover and AC charging connector are present.

Signals to check

These diagnostic fields are associated with CP_a163. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cover 1 Open Counts CP_a163_cover1OpenCounts %
Cover 1 State CP_a163_cover1State
0
BOOT UP CLOSED
1
CLOSED
2
OPEN
3
SHORT TO GND
4
SHORT TO VBAT
5
SNA
—
Cover 2 Open Counts CP_a163_cover2OpenCounts %
Cover 2 State CP_a163_cover2State
0
BOOT UP CLOSED
1
CLOSED
2
OPEN
3
SHORT TO GND
4
SHORT TO VBAT
5
SNA
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a163.

Browse all CP alert codes