Alert description

AC charging is unavailable because the charge port (CP) electronic control unit (ECU) has detected that the CP AC charging connector is not present on the back of the CP inlet.

Potential impact

AC charging will be unavailable.

Set condition

The CP ECU detects the charge port AC charging connector is not present.

Clear condition

The CP ECU detects the AC charging connector is present.

Signals to check

These diagnostic fields are associated with CP_a173. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cover 1 Open Counts CP_a173_cover1OpenCounts %
Cover 1 State CP_a173_cover1State
0
BOOT UP CLOSED
1
CLOSED
2
OPEN
3
SHORT TO GND
4
SHORT TO VBAT
5
SNA
—
Cover 2 Open Counts CP_a173_cover2OpenCounts %
Cover 2 State CP_a173_cover2State
0
BOOT UP CLOSED
1
CLOSED
2
OPEN
3
SHORT TO GND
4
SHORT TO VBAT
5
SNA
—