CP_a110 — Thermal Velocity High
Full alert identifier: CP_a110_thermalVelocityHigh
Alert description
The charge port (CP) electronic control unit (ECU) detects an unexpected rapid rise in temperature.
Potential impact
DC charging is terminated and is blocked until the charge cable is disconnected.
Set condition
The CP ECU detects that thermal velocity, which is calculated each minute, exceeds the expected increase rate of temperature.
Clear condition
The charge cable is disconnected.
Signals to check
These diagnostic fields are associated with CP_a110. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Thermal Velocity
CP_
|
C/min |
Thermistor Id
CP_
|
— |
Thermistor Temp
CP_
|
C |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a110.