Skip to content

CP_a095 — Thermal Dc Limit Active

Full alert identifier: CP_a095_thermalDcLimitActive

Alert description

The charge port DC pin temperatures have entered a region where its thermal foldback limits are dynamically changing

Potential impact

DC charge current may be limited

Set condition

The charge port DC pin temperature hits its active threshold

Clear condition

The charge port DC pin temperature drops 5C below its active threshold

Signals to check

These diagnostic fields are associated with CP_a095. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temp CP_a095_ambientTemp C
Dc Output Current CP_a095_dcOutputCurrent A
Fc Brand CP_a095_fcBrand
0
SNA
1
TESLA
—
Fc Type CP_a095_fcType
0
SUPERCHARGER
1
CHADEMO
2
GB
3
CC EVSE
4
COMBO
5
MC EVSE
6
OTHER
7
SNA
—
Pack Current CP_a095_packCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a095.

Browse all CP alert codes