CP_a095 — Thermal Dc Limit Active
Full alert identifier: CP_a095_thermalDcLimitActive
Alert description
The charge port DC pin temperatures have entered a region where its thermal foldback limits are dynamically changing
Potential impact
DC charge current may be limited
Set condition
The charge port DC pin temperature hits its active threshold
Clear condition
The charge port DC pin temperature drops 5C below its active threshold
Signals to check
These diagnostic fields are associated with CP_a095. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ambient Temp
CP_
|
C |
Dc Output Current
CP_
|
A |
Fc Brand
CP_
|
— |
Fc Type
CP_
|
— |
Pack Current
CP_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a095.