CP_a153 — Thermal Ac Limit Active
Full alert identifier: CP_a153_thermalAcLimitActive
Alert description
The charge port inlet pin temperature has reached a level where limiting AC charge current is necessary until temperature returns to normal operating range.
Potential impact
AC charge current is limited.
Set condition
The charge port inlet pin temperature reaches an unexpected level (temperature detected exceeds normal operating range).
Clear condition
The charge port inlet pin temperature returns to an acceptable level (within normal operating range).
Signals to check
These diagnostic fields are associated with CP_a153. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ac Pin Temp 1
CP_
|
C |
Ac Pin Temp 2
CP_
|
C |
Ac Pin Temp Velocity
CP_
|
C/min |
Ambient Temp
CP_
|
C |
Pcs Line Charge Current
CP_
|
A |
Check other alerts