Skip to content

CP_a086 — Dc Pin Temp Irrational

Full alert identifier: CP_a086_dcPinTempIrrational

Alert description

The charge port (CP) electronic control unit (ECU) detects an open circuit on the DC pin thermistor.

Potential impact

DC charging does not start.

Set condition

The CP ECU detects that the DC pin temperature is less than the open circuit threshold for more than 1 second.

Clear condition

The CP ECU detects that the DC pin temperature is greater than the open circuit threshold for more than 1 second.

Signals to check

These diagnostic fields are associated with CP_a086. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dc Pin Temp CP_a086_dcPinTemp C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a086.

Browse all CP alert codes