CP_a086 — Dc Pin Temp Irrational
Full alert identifier: CP_a086_dcPinTempIrrational
Alert description
The charge port (CP) electronic control unit (ECU) detects an open circuit on the DC pin thermistor.
Potential impact
DC charging does not start.
Set condition
The CP ECU detects that the DC pin temperature is less than the open circuit threshold for more than 1 second.
Clear condition
The CP ECU detects that the DC pin temperature is greater than the open circuit threshold for more than 1 second.
Signals to check
These diagnostic fields are associated with CP_a086. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Dc Pin Temp
CP_
|
C |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a086.