CP_a085 — Dc Pin Temp Faulted
Full alert identifier: CP_a085_dcPinTempFaulted
Alert description
The charge port inlet pin temperature has reached an unacceptable level (greatly exceeds normal operating range), causing DC charging to stop.
Potential impact
DC charging will be interrupted and remain unavailable until a charge cable cycle occurs (disconnect and reconnect) and the charge port inlet pin temperature returns to normal operating range.
Set condition
The charge port inlet pin temperature reaches a level where it is unacceptable to continue DC charging (temperature detected greatly exceeds normal operating range).
Clear condition
The charge cable is disconnected from the charge port inlet or the DC inlet pin temperature is irrational. Note: Alert will continue to set until the charge port inlet pin temperature is detected within normal operating range.
Signals to check
These diagnostic fields are associated with CP_a085. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Absolute Temp Fault
CP_
|
— |
Dc Pin Temp
CP_
|
C |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a085.