Skip to content

CP_a085 — Dc Pin Temp Faulted

Full alert identifier: CP_a085_dcPinTempFaulted

Alert description

The charge port inlet pin temperature has reached an unacceptable level (greatly exceeds normal operating range), causing DC charging to stop.

Potential impact

DC charging will be interrupted and remain unavailable until a charge cable cycle occurs (disconnect and reconnect) and the charge port inlet pin temperature returns to normal operating range.

Set condition

The charge port inlet pin temperature reaches a level where it is unacceptable to continue DC charging (temperature detected greatly exceeds normal operating range).

Clear condition

The charge cable is disconnected from the charge port inlet or the DC inlet pin temperature is irrational. Note: Alert will continue to set until the charge port inlet pin temperature is detected within normal operating range.

Signals to check

These diagnostic fields are associated with CP_a085. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Absolute Temp Fault CP_a085_absoluteTempFault —
Dc Pin Temp CP_a085_dcPinTemp C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a085.