Skip to content

CP_a140 — Supercharger Faulted

Full alert identifier: CP_a140_superchargerFaulted

Alert description

A Supercharger post communicating over single wire controller area network (SWCAN) reports that it has encountered an issue.

Potential impact

Charging does not start or is interrupted.

Set condition

The Supercharger reports via SWCAN that it has entered the faulted state.

Clear condition

The Supercharger post reports via SWCAN that it is no longer in the faulted state, or the cable is disconnected.

Signals to check

These diagnostic fields are associated with CP_a140. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
CP Proximity CP_a140_CP_proximity
0
SNA
1
DISCONNECTED
2
UNLATCHED
3
LATCHED
—
Latch State CP_a140_latchState
0
SNA
1
DISENGAGED
2
ENGAGED
3
BLOCKING
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a140.

Browse all CP alert codes