CC_a013 — Veh Conn OT
Full alert identifier: CC_a013_vehConnOT
Alert description
Wall connector charge handle temperature too high.
Potential impact
Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.
Set condition
Wall connector charge handle temperature exceeds 78 degC.
Clear condition
Wall connector charge handle temperature falls below 58 degC or user interaction if charging was stopped.
Signals to check
These diagnostic fields are associated with CC_a013. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Handle Temp
CC_
|
DegC |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a013.