Skip to content

CC_a011 — Ambient OT

Full alert identifier: CC_a011_ambientOT

Alert description

Wall connector printed circuit board assembly (PCBA) temperature is too high.

Potential impact

Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.

Set condition

Wall connector PCBA temperature exceeds 100 degC.

Clear condition

Wall connector PCBA temperature falls below 80 degC or user interaction if charging was stopped.

Signals to check

These diagnostic fields are associated with CC_a011. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Pcba Temp CC_a011_pcbaTemp DegC

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a011.