CC_a012 — Wall Plug OT
Full alert identifier: CC_a012_wallPlugOT
Alert description
Wall connector input wiring temperature is too high.
Potential impact
Wall connector will reduce reported current capability in 25 percent increments until condition clears, or current reaches 0 and charging is stopped.
Set condition
Wall connector input wiring temperature exceeds 100 degC.
Clear condition
Wall connector input wiring temperature falls below 80 degC or user interaction if charging was stopped.
Signals to check
These diagnostic fields are associated with CC_a012. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Input Thermopile
CC_
|
V |
Input Thermopile Dvdt
CC_
|
V/sec |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a012.