Falcon Wing door controller alerts
Browse 161 BCFALCD alert codes and open an entry for its description and recorded conditions.
BCFALCD alert codes
Showing 1–50 of 161
- BCFALCD_a001 — Watchdog Reset BCFALCD_a001_WatchdogReset Warns if the processor has experienced a reset due to watchdog reset.
- BCFALCD_a002 — Power Loss Reset BCFALCD_a002_PowerLossReset Warns if the processor has experienced a reset due to power loss.
- BCFALCD_a003 — SW Assertion BCFALCD_a003_SWAssertion An internal software assertion has failed.
- BCFALCD_a004 — CANMIA BCFALCD_a004_CANMIA The SBC CAN transceiver has faulted. Alert will be seen if the trasnceiver has recovered from the faulted condition.
- BCFALCD_a005 — CANTX Error BCFALCD_a005_CANTXError An error has been detected with CAN transmission. Used by engineering to debug.
- BCFALCD_a006 — CANTX cyclic Error BCFALCD_a006_CANTX_cyclicError An error has been detected within the CANTX cyclic dispatcher generated code. Used by engineering to debug.
- BCFALCD_a010 — Ext Supply Volt Error BCFALCD_a010_ExtSupplyVoltError The vehicle controller detects the supply voltage from 1 or more components is outside of the expected range.
- BCFALCD_a012 — CPU Reset BCFALCD_a012_CPUReset CPU detected a reset.
- BCFALCD_a013 — Alert Manager Fault BCFALCD_a013_AlertManagerFault Alert Manager encountered an internal processing error.
- BCFALCD_a014 — Bridge Fault BCFALCD_a014_BridgeFault Bridge faults are most likely due to configuration error.
- BCFALCD_a015 — NVMM Error BCFALCD_a015_NVMMError An issue is indicated from the non-volatile memory manager.
- BCFALCD_a016 — NVMM Record Error BCFALCD_a016_NVMMRecordError An issue is indicated from a particular non-volatile memory record.
- BCFALCD_a017 — Awake For Too Long BCFALCD_a017_AwakeForTooLong
- BCFALCD_a021 — Task Scheduler Error BCFALCD_a021_TaskSchedulerError If a task was not able to run at the appropriate time.
- BCFALCD_a022 — Task Init Error BCFALCD_a022_TaskInitError If a task failed to initialize.
- BCFALCD_a025 — Crash Event BCFALCD_a025_CrashEvent
- BCFALCD_a029 — Core Dump BCFALCD_a029_CoreDump Indicates an exception occurred and core dump data is present.
- BCFALCD_a030 — ECU Log Upload Request BCFALCD_a030_ECULogUploadRequest Triggers on board diagnostics service to upload log buffer.
- BCFALCD_a031 — UDS Active BCFALCD_a031_UDSActive A unified diagnostics services (UDS) request was made
- BCFALCD_a032 — Actuator12 V Fault BCFALCD_a032_actuator12VFault
- BCFALCD_a034 — Falcon Open At Speed BCFALCD_a034_FalconOpenAtSpeed The Falcon Door Body Controller has detected a falcon door is open and the vehicle speed exceeds 0.5KPH.
- BCFALCD_a035 — Chassis Collision BCFALCD_a035_ChassisCollision
- BCFALCD_a036 — Door USS Invaliddist BCFALCD_a036_doorUSSInvaliddist Door outward ultrasonic sensor (USS) reports an invalid obstacle distance.
- BCFALCD_a037 — Door USS Possible False Object Detection BCFALCD_a037_doorUSSPossibleFalseObjectDetection The rear door's outward ultrasonic sensor is detecting an obstacle at a very close distance for an extended period of time, likely indicating a false object detection
- BCFALCD_a041 — High CPU Load BCFALCD_a041_HighCPULoad CPU under heavy load.
- BCFALCD_a042 — High Stack Usage BCFALCD_a042_HighStackUsage High stack memory usage was detected
- BCFALCD_a043 — Task1ms Error BCFALCD_a043_Task1msError Debug information for 1ms task errors.
- BCFALCD_a044 — Task10ms Error BCFALCD_a044_Task10msError Debug information for 10ms task errors
- BCFALCD_a045 — Task100ms Error BCFALCD_a045_Task100msError Debug information for 100ms task errors.
- BCFALCD_a046 — Task1000ms Error BCFALCD_a046_Task1000msError Debug information for 1000ms task errors.
- BCFALCD_a047 — Roof USS Invaliddist BCFALCD_a047_roofUSSInvaliddist Roof USS reports an invalid obstacle distance.
- BCFALCD_a050 — Side Config Error BCFALCD_a050_sideConfigError The body controller detects a side configuration error, which may prevent the Falcon door from opening or closing.
- BCFALCD_a051 — Blocked Door Request BCFALCD_a051_BlockedDoorRequest Same successive door request received wihtin short time frame, see alert payload for more information.
- BCFALCD_a052 — USS RH Over Temp BCFALCD_a052_USS_RHOverTemp Check SNS USS_alertMatrix for specific details of this alert.
- BCFALCD_a053 — USS RH Sns Blocked BCFALCD_a053_USS_RHSnsBlocked Check SNS USS_alertMatrix for specific details of this alert
- BCFALCD_a054 — USS RH Sns Intrnl Fail BCFALCD_a054_USS_RHSnsIntrnlFail The ultrasonic sensor (USS) controller detects an internal condition affecting the passenger-side USS.
- BCFALCD_a055 — USS RH Lin Comm Error BCFALCD_a055_USS_RHLinCommError The ultrasonic sensor (USS) controller detects a condition affecting the Local Interconnect Network (LIN) communication with the passenger-side USS.
- BCFALCD_a056 — USS LH Over Temp BCFALCD_a056_USS_LHOverTemp Check SNS USS_alertMatrix for specific details of this alert
- BCFALCD_a057 — USS LH Sns Blocked BCFALCD_a057_USS_LHSnsBlocked Check SNS USS_alertMatrix for specific details of this alert
- BCFALCD_a058 — Input R High Sync Debug BCFALCD_a058_inputRHighSyncDebug Voltage drop on input power is high
- BCFALCD_a059 — Input Resistance High BCFALCD_a059_inputResistanceHigh A large voltage drop is detected in the input power to the vehicle controller, indicating the resistance on the input power feed to the vehicle controller is higher than expected.
- BCFALCD_a060 — Engineering Build BCFALCD_a060_engineeringBuild The software installed on the vehicle is intended for engineering use and development purposes only. The vehicle software may have some expected features disabled for testing purposes, or include new features whose function is not yet full…
- BCFALCD_a061 — X CP Connected BCFALCD_a061_XCPConnected Indicates an active connection to the universal measurement and calibration protocol state machine
- BCFALCD_a062 — X CP Was Connected BCFALCD_a062_XCPWasConnected Indicates there was an active connection to the universal measurement and calibration protocol state machine
- BCFALCD_a063 — Switch Fault BCFALCD_a063_SwitchFault A condition affecting switch functionality has been detected.
- BCFALCD_a064 — Bus Sleep Req Timeout BCFALCD_a064_busSleepReqTimeout Indicates if a bus has timed out of a sleep request from the network manager
- BCFALCD_a079 — Dvr Side Cfg Mismatch BCFALCD_a079_DvrSideCfgMismatch reseting the controller should fix the issue
- BCFALCD_a083 — Falcon Pinch Fault BCFALCD_a083_FalconPinchFault The Falcon door controller detected a condition affecting the functionality of one or both of the pinch strips.
- BCFALCD_a086 — Calibration Required BCFALCD_a086_CalibrationRequired The Falcon door needs to be calibrated, which can be done by holding the B pillar close switch until ~2 seconds after door is latched.
- BCFALCD_a087 — Upper Sag Prevention BCFALCD_a087_UpperSagPrevention Upper door section struts were actuated to prevent the door from sagging (lowering).