BCFALCD_a010 — Ext Supply Volt Error
Full alert identifier: BCFALCD_a010_ExtSupplyVoltError
Alert description
The vehicle controller detects the supply voltage from 1 or more components is outside of the expected range.
Potential impact
Features depending on the vehicle controller functionality may be unavailable or may not function as expected.
Set condition
The vehicle controller detects the supply voltage from 1 or more components is < 7.31. Alert log signal data should provide more information on the specific condition(s) detected.
Clear condition
The vehicle controller detects the supply voltage from all components is > 7.31 V.
Signals to check
These diagnostic fields are associated with BCFALCD_a010. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Under Voltage Detected
BCFALCD_
|
— |
Under Voltage Timeout
BCFALCD_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCD_a010.