Skip to content
Model X

BCFALCD_a086 — Calibration Required

Full alert identifier: BCFALCD_a086_CalibrationRequired

Alert description

The Falcon door needs to be calibrated, which can be done by holding the B pillar close switch until ~2 seconds after door is latched.

Potential impact

Uncalibrated doors will not respond to movement commands and triple beep.

Set condition

Falcon door has never been calibrated, or calibration has been lost due to unexpected event like 12V loss or unexpected latch closing.

Clear condition

Falcon door is calibrated.

Signals to check

These diagnostic fields are associated with BCFALCD_a086. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Calibration Needed BCFALCD_a086_calibrationNeeded —
Uncal Reason BCFALCD_a086_uncalReason
0
NONE
1
INIT NOT CLOSED
2
UNEXPECTED MOVE FROM CLOSED
3
OPEN LOOP FAULT
4
POSITION FAULT
5
IMPLAUSIBLE ANGLES
6
EXTERNAL REQUEST
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFALCD_a086.

Browse all BCFALCD alert codes