VCFRONT_a511 — DCDC Saturation Load Shed
Full alert identifier: VCFRONT_a511_DCDCSaturationLoadShed
Alert description
Electrical current flowing through the power conversion system (PCS) eFuse is approaching the DCDC converter's maximum handling capacity. The front vehicle controller (VCFRONT) is shedding some vehicle electrical loads by cutting power to less essential electronic control units (ECUs).
Potential impact
Some convenience features will be unavailable as VCFRONT limits LV electrical system current draw by cutting power to some electronic control units (ECUs).
Set condition
The PCS eFuse current value is within 20A of the DCDC converter's maximum handling capacity for 5 seconds.
Clear condition
The PCS eFuse current value remains lower than the DCDC converter's maximum handling capacity long enough for VCFRONT to stop loadshedding (until DCDC Saturation Loadshed Stage is MIN).
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
DCDC Max Output Current Allowed
VCFRONT_
|
A |
PCSE Fuse Current
VCFRONT_
|
A |
| Signal | Unit |
|---|---|
DCDC Output Is Limited
VCFRONT_
|
— |
PCS Signals Are Valid
VCFRONT_
|
— |
Factory Gated
VCFRONT_
|
— |
Frunk Open
VCFRONT_
|
— |
Hv State
VCFRONT_
|
— |
Service Mode
VCFRONT_
|
— |
Vehicle Is Updating
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a511.