VCFRONT_a508 — Bridge eFuse Load Shed

Full alert identifier: VCFRONT_a508_bridgeEFuseLoadShed

Alert description

Electrical current flowing through the Bridge eFuse has equaled or exceeded 120A. The Bridge eFuse circuit may open (trip) if low voltage (LV) electrical system loads are not reduced. The front vehicle controller (VCFRONT) is shedding some vehicle electrical loads by cutting power to less essential electronic control units (ECUs).

Potential impact

Some convenience features will be unavailable as VCFRONT limits LV electrical system current draw by cutting power to some electronic control units (ECUs).

Set condition

The Bridge eFuse current value equals or exceeds 120A for 100 milliseconds.

Clear condition

The Bridge eFuse current value remains below 120A long enough for VCFRONT to stop loadshedding (until Bridge eFuse Loadshed Stage is MIN).

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ambient Temp VCFRONT_a508_ambientTemp degC
Bridge E Fuse Current VCFRONT_a508_bridgeEFuseCurrent A
Bridge E Fuse Temp VCFRONT_a508_bridgeEFuseTemp degC
Signal Unit
Frunk Open VCFRONT_a508_frunkOpen —
Service Mode VCFRONT_a508_serviceMode —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a508.